2006 GOSHEN GC II
View all complaints and recalls for this specific model year.
2006 GOSHEN GC II Summary
2006
Model Year
0
Total Complaints
3
Total Recalls
2384
Vehicles Affected
Recalls
2006 GOSHEN GC II
342 vehicles affected
EQUIPMENT
Goshen Coach is recalling certain buses as follows: GC II, model years 2006-2012; GCII-550, model years 2007-2009; G-Force, model years 2011-2012; Pacer, model years 2006-2012; Pacer LS, model years 2008, 2010, and 2013; Pacer LTD, model year 2012; and Sentinel, model year 2011. The buses are equipped with a Ricon manufactured wheelchair lift which has an optional armored pendant cable. The cable may have been installed such that it doesn't clear the wheelchair lift and without a protective cover, or a misinstalled protective cover.
Risk: The cable may contact the power lug at the base of the wheel chair lift causing a short circuit that could result in a fire.
2006 GOSHEN GC II
2017 vehicles affected
EQUIPMENT:APPLIANCE:AIR CONDITIONER
GOSHEN COACH IS RECALLING CERTAIN MODEL YEAR 2006-2011 BUSES EQUIPPED WITH CARRIER GENV EM-1 EVAPORATOR UNITS. DUE TO TIME, TEMPERATURE, AND/OR VIBRATION, THE FUSE MAY LOOSEN IN THE FUSE HOLDER RESULTING IN HIGH RESISTANCE AND ARCING.
Risk: IF SUFFICIENT ARCING OCCURS, THE FUSE HOLDER MAY MELT, AND MAY BE ACCOMPANIED BY FLAME, SMOKE AND POTENTIAL FIRE.
2006 GOSHEN GC II
25 vehicles affected
EQUIPMENT
GOSHEN COACH IS RECALLING CERTAIN MODEL YEAR 2006-2007 GOSHEN GC II MOTOR HOMES EQUIPPED WITH TRANS AIR TA 73 EVAPORATORS. THE EVAPORATOR UTILIZES A POWER RESISTOR TO REGULATE BLOWER SPEED. SHOULD A SHORT OCCUR IN THE "LOW OR MEDIUM SPEED" CIRCUIT WHILE THE BLOWER IS IN HIGH SPEED, THE SHORT WILL CAUSE THE SUPPLY VOLTAGE TO FEEDBACK THROUGH THE RESISTOR TO GROUND, NOT DRAWING ENOUGH CURRENT TO TRIP THE FUSE.
Risk: THIS WOULD CAUSE THE RESISTOR TEMPERATURE TO RISE TO A POINT WHERE IT WILL MELT AND POSSIBLY IGNITE THE PLASTIC BLOWER HOUSING TO WHICH IT IS MOUNTED. THE OVERHEATING CAN RESULT IN A FIRE.
Complaints